Row-by-row data description
I’ll start off the same way as in
vignette('how-to-use-rvdat')
:
- Locating
vdat.exe
withvdat_here
- Downloading the example VRL file from the
glatos
package - Converting the VRL to a CSV using
vdat_to_csv
library(rvdat)
td <- file.path(
tempdir(),
"vignette"
)
dir.create(
td
)
vdat_here()
#> i Looking for vdat in the typical locations.
#> i vdat is located at C:/Program Files/Innovasea/Fathom Connect/vdat.exe
download.file(
url = file.path(
"https://github.com/ocean-tracking-network/glatos/raw/dev/inst/extdata",
"detection_files_raw/VR2AR_546310_20190613_1.vrl"
),
destfile = file.path(td, "VR2AR_546310_20190613_1.vrl"),
mode = "wb",
quiet = TRUE
)
vdat_to_csv(file.path(td, "VR2AR_546310_20190613_1.vrl"),
outdir = td
)
#> 0.0% - Converting File
7.6% - Converting File
9.2% - Converting File
10.7% - Converting File
12.2% - Converting File
13.7% - Converting File
15.3% - Converting File
16.8% - Converting File
18.3% - Converting File
19.8% - Converting File
21.4% - Converting File
22.9% - Converting File
24.4% - Converting File
26.0% - Converting File
27.5% - Converting File
29.0% - Converting File
30.5% - Converting File
32.1% - Converting File
33.6% - Converting File
35.1% - Converting File
36.6% - Converting File
38.2% - Converting File
39.7% - Converting File
41.2% - Converting File
42.7% - Converting File
44.3% - Converting File
45.8% - Converting File
47.3% - Converting File
48.9% - Converting File
50.4% - Converting File
51.9% - Converting File
53.4% - Converting File
55.0% - Converting File
56.5% - Converting File
58.0% - Converting File
59.5% - Converting File
61.1% - Converting File
62.6% - Converting File
64.1% - Converting File
65.6% - Converting File
67.2% - Converting File
68.7% - Converting File
70.2% - Converting File
71.8% - Converting File
73.3% - Converting File
74.8% - Converting File
76.3% - Converting File
77.9% - Converting File
79.4% - Converting File
80.9% - Converting File
82.4% - Converting File
84.0% - Converting File
85.5% - Converting File
87.0% - Converting File
88.5% - Converting File
90.1% - Converting File
91.6% - Converting File
93.1% - Converting File
94.7% - Converting File
96.2% - Converting File
97.7% - Converting File
100.0% - Converting File
#> v File converted:
#> C:\Users\darpa2\AppData\Local\Temp\RtmpusjJ5z/vignette/VR2AR_546310_20190613_1.vrl
#> i File saved in:
#> C:\Users\darpa2\AppData\Local\Temp\RtmpusjJ5z/vignette/VR2AR_546310_20190613_1.csv
list.files(td, pattern = "VR2AR")
#> [1] "VR2AR_546310_20190613_1.csv" "VR2AR_546310_20190613_1.vrl"
Exploring the VDAT CSV’s data structure
Now for the fun part: what does the csv look like?
exported_csv <- read.csv(
file.path(td, "VR2AR_546310_20190613_1.csv")
)
#> Error in read.table(file = file, header = header, sep = sep, quote = quote, : more columns than column names
Uh oh! Something weird! utils::read.csv
guesses how many
columns there should be by looking at the first five lines of the data.
Here, it took a guess and more columns showed up later. Let’s skip that
process by telling it that the first row does not contain column names
by using header = FALSE
.
exported_csv <- read.csv(
file.path(td, "VR2AR_546310_20190613_1.csv"),
header = FALSE
)
head(exported_csv)
#> V1 V2
#> 1 \357\273\277VEMCO DATA LOG 2.0.0
#> 2 RECORD TYPE FIELD
#> 3 ATTITUDE_DESC Device Time (UTC)
#> 4 BATTERY_DESC Device Time (UTC)
#> 5 CFG_CHANNEL_DESC Device Time (UTC)
#> 6 CFG_STATION_DESC Device Time (UTC)
#> V3 V4
#> 1 vdat-11.0.1-20240830-d01c0d-release
#> 2 FIELD FIELD
#> 3 Time Time Offset (h)
#> 4 Time Time Offset (h)
#> 5 Time Time Offset (h)
#> 6 Time Time Offset (h)
#> V5 V6 V7 V8
#> 1
#> 2 FIELD FIELD FIELD FIELD
#> 3 Time Correction (s) Model Serial Number Tilt (deg)
#> 4 Time Correction (s) Model Serial Number Battery Position
#> 5 Time Correction (s) Model Serial Number Channel
#> 6 Time Correction (s) Model Serial Number Station Name
#> V9 V10 V11
#> 1
#> 2 FIELD FIELD FIELD
#> 3
#> 4 Battery Type Battery Serial Number Battery Voltage (V)
#> 5 Detection Type Frequency (kHz) Blanking (ms)
#> 6 Latitude (deg) Longitude (deg)
#> V12 V13 V14 V15 V16 V17 V18 V19
#> 1
#> 2 FIELD FIELD FIELD FIELD FIELD FIELD FIELD FIELD
#> 3
#> 4 Battery Remaining (%)
#> 5 Map ID Coding ID
#> 6
#> V20 V21 V22 V23 V24 V25 V26
#> 1
#> 2 FIELD FIELD FIELD FIELD FIELD FIELD FIELD
#> 3
#> 4
#> 5
#> 6
I suggest that you skim through the data frame with the
View
function. You’ll find that it has a few
properties:
The first row contains metadata about vdat.exe
,
itself.
exported_csv[1, ]
#> V1 V2 V3 V4 V5 V6
#> 1 \357\273\277VEMCO DATA LOG 2.0.0 vdat-11.0.1-20240830-d01c0d-release
#> V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24
#> 1
#> V25 V26
#> 1
While there are 26 columns as a separate row takes that many fields to describe its data structure (see the next section), only the first three are pertinent.
- This is a VEMCO data log;
- It is using version 2.0.0 of the schema;
- It was created with some specific vdat version.
- Note that this does, in fact, match the version of
vdat
we are using. This can be found usingrvdat::vdat_version
.
vdat_version()
#> vdat-11.0.1-20240830-d01c0d-release
The next 20+ lines contain the column names of different subsets of the data.
These subsets are by variable, such as tilt angle, temperature, and
the like. They are designated as descriptions by appending
_DESC
to the variable name in the form
<variable>_DESC
(Description – DESC. Get it?). This
is the reason we couldn’t import the CSV the first time – there are a
different number of columns for each variable, and thus the data was
more jagged than read.csv
expected.
exported_csv[2:5, ]
#> V1 V2 V3 V4
#> 2 RECORD TYPE FIELD FIELD FIELD
#> 3 ATTITUDE_DESC Device Time (UTC) Time Time Offset (h)
#> 4 BATTERY_DESC Device Time (UTC) Time Time Offset (h)
#> 5 CFG_CHANNEL_DESC Device Time (UTC) Time Time Offset (h)
#> V5 V6 V7 V8
#> 2 FIELD FIELD FIELD FIELD
#> 3 Time Correction (s) Model Serial Number Tilt (deg)
#> 4 Time Correction (s) Model Serial Number Battery Position
#> 5 Time Correction (s) Model Serial Number Channel
#> V9 V10 V11
#> 2 FIELD FIELD FIELD
#> 3
#> 4 Battery Type Battery Serial Number Battery Voltage (V)
#> 5 Detection Type Frequency (kHz) Blanking (ms)
#> V12 V13 V14 V15 V16 V17 V18 V19
#> 2 FIELD FIELD FIELD FIELD FIELD FIELD FIELD FIELD
#> 3
#> 4 Battery Remaining (%)
#> 5 Map ID Coding ID
#> V20 V21 V22 V23 V24 V25 V26
#> 2 FIELD FIELD FIELD FIELD FIELD FIELD FIELD
#> 3
#> 4
#> 5
The next ~7 rows contain receiver configuration
After a row designated as DATA_SOURCE_FILE
, there are a
few rows which outline the receiver’s configuration; this file has 6
total. These are things like the initialization time, Map ID, whether an
internal transmitter is turned on (and its delay), etc..
first_data_row <- which(exported_csv$V1 == "DATA_SOURCE_FILE")
exported_csv[first_data_row:(first_data_row + 6), ]
#> V1 V2
#> 28 DATA_SOURCE_FILE VR2AR_546310_20190613_1.vrl
#> 29 EVENT_INIT 2019-06-11 02:44:16
#> 30 CLOCK_REF 2019-06-11 02:44:16
#> 31 CFG_CHANNEL 2019-06-11 02:44:16
#> 32 CFG_TRANSMITTER 2019-06-11 02:44:16
#> 33 CFG_TRANSMITTER 2019-06-11 02:44:27
#> 34 CFG_TRANSMITTER 2019-06-11 02:44:34
#> V3
#> 28 ffee6ee7-450a-db42-b54c-334b672fddf5
#> 29
#> 30
#> 31
#> 32
#> 33
#> 34
#> V4 V5 V6 V7
#> 28 com.vemco.file.vrl.0207.ff02.ff02/5.0.1 110026 ORIGINAL
#> 29 VR2AR-69 546310
#> 30 VR2AR-69 546310
#> 31 VR2AR-69 546310
#> 32 VR2AR-69 546310
#> 33 VR2AR-69 546310
#> 34 VR2AR-69 546310
#> V8 V9 V10 V11 V12
#> 28
#> 29 2019-06-11 02:44:11 UTC-04:00 5.0.1
#> 30 2019-06-11 02:44:16 0 INITIALIZATION
#> 31 1 PPM 69 260 MAP-113
#> 32 PPM A69-1601-60774 60774 DISABLED 540
#> 33 PPM A69-1601-60774 60774 DISABLED 540
#> 34 PPM A69-1601-60774 60774 DISABLED 540
#> V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 V26
#> 28
#> 29
#> 30
#> 31
#> 32 660
#> 33 660
#> 34 660
Logged data!
“‘And now,’ cried Max, ‘let the wild rumpus start!’”
Depending on how long you’ve had your receiver deployed, you could have many thousands of rows after this. If you’re logging environmental data you’ll have on the order of four rows per minute deployed (temperature, depth, tilt, and general diagnostics), as well as one for every logged detection.
exported_csv[(first_data_row + 7):(first_data_row + 7 + 7), ]
#> V1 V2 V3 V4 V5 V6 V7 V8 V9
#> 35 DIAG_FAST 2019-06-11 02:45:00 VR2AR-69 546310 17.064 150
#> 36 TEMP 2019-06-11 02:45:00 VR2AR-69 546310 17.064
#> 37 DEPTH 2019-06-11 02:45:00 VR2AR-69 546310 0
#> 38 ATTITUDE 2019-06-11 02:45:00 VR2AR-69 546310 2
#> 39 DIAG_FAST 2019-06-11 02:46:00 VR2AR-69 546310 17.129 161
#> 40 TEMP 2019-06-11 02:46:00 VR2AR-69 546310 17.129
#> 41 DEPTH 2019-06-11 02:46:00 VR2AR-69 546310 0
#> 42 ATTITUDE 2019-06-11 02:46:00 VR2AR-69 546310 3
#> V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 V26
#> 35 2 0
#> 36
#> 37
#> 38
#> 39 3 0
#> 40
#> 41
#> 42
Diagnostic rows (DIAG
) will have the hourly mean of
TEMP
, DEPTH
, and ATTITUDE
rows,
as well as detections/pings. If you have fast diagnostics on, rows
labeled with DIAG_FAST
will contain the same per-minute
data as TEMP
/DEPTH
/ATTITUDE
.
exported_csv[(exported_csv$V1 == "DIAG"), ][1, ]
#> V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11
#> 95 DIAG 2019-06-11 03:00:00 VR2AR-69 546310 17.744 150 87 0
#> V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 V26
#> 95 0 0
Detections are logged to the tenth of a millisecond
That’s seconds. Whether that’s accurate or just over-precise… I don’t know.
Detections are indicated by a row labeled with DET
,
followed by the raw logged time, time-corrected time if applicable, and
information about the transmitter.
exported_csv[(exported_csv$V1 == "DET"), ][1, ]
#> V1 V2 V3 V4 V5 V6 V7 V8 V9
#> 2566 DET 2019-06-11 13:03:32.0837 VR2AR-69 546310 1 PPM
#> V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22
#> 2566 A69-1601-57060 57060
#> V23 V24 V25 V26
#> 2566
The last three rows are data associated with the download
The internal transmitter configuration, time associated with the internal and downloading-computer clocks, and the download, itself, are all reported.
tail(exported_csv)
#> V1 V2 V3 V4 V5 V6 V7
#> 16748 TEMP 2019-06-13 17:30:00 VR2AR-69 546310
#> 16749 DEPTH 2019-06-13 17:30:00 VR2AR-69 546310
#> 16750 ATTITUDE 2019-06-13 17:30:00 VR2AR-69 546310
#> 16751 CFG_TRANSMITTER 2019-06-13 17:30:34 VR2AR-69 546310
#> 16752 CLOCK_REF 2019-06-13 17:30:53 VR2AR-69 546310
#> 16753 EVENT_OFFLOAD 2019-06-13 17:30:53 VR2AR-69 546310
#> V8 V9 V10 V11 V12 V13
#> 16748 21.21
#> 16749 0
#> 16750 2
#> 16751 PPM A69-1601-60774 60774 DISABLED 540 660
#> 16752 2019-06-13 17:30:54 1 OFFLOAD
#> 16753 2019-06-13 17:30:54 UTC-04:00 1328 99.6235 51
#> V14 V15 V16 V17 V18 V19 V20 V21 V22 V23
#> 16748
#> 16749
#> 16750
#> 16751
#> 16752
#> 16753 VR2AR_546310_20190613_1.vrl
#> V24 V25 V26
#> 16748
#> 16749
#> 16750
#> 16751
#> 16752